Skip to content

Extracting interactions (Interaction)

This tool automatically extracts intramolecular and intermolecular atomic contacts (candidate interactions such as hydrogen bonds) and displays them as lines and labels of a measurement display (atomintr). Open the Interaction analysis dialog with Tools > Interaction....

Screenshot planned

Dialog items

Molecule

Item Default Description
Molecule / selection — The molecule to extract interactions from, and the part of it to target. If the selection is empty, all atoms are targeted
Second molecule OFF When ON, you can choose a second molecule. Interactions between the first selection and the second molecule are extracted
Second selection OFF When ON, you can specify a second selection. Only interactions spanning the first selection and the second selection are extracted

The second selection applies to the second molecule if Second molecule is ON, and to the first molecule if it is OFF. If you choose the same molecule as the first one for the second molecule, the second molecule setting is ignored.

Parameters

Item Default Description
Min distance (A) 2.5 Minimum distance (Å) to count as an interaction
Max distance (A) 3.5 Maximum distance (Å) to count as an interaction. Must be larger than Min distance
Max labels 30 Maximum number of interactions to extract (1 to 1000)
Hydrogen bond (N, O) only OFF When ON, pairs involving carbon atoms are excluded (in proteins, only pairs of atoms such as N and O remain)
Label set name measure Name of the atomintr Renderer to which the interactions are added. It is created if it does not exist

Each time you open the dialog, all items other than the molecule return to their defaults.

Hydrogen bond geometry is not considered

What is extracted is the set of atom pairs that satisfy the distance condition; hydrogen bond geometry and the like are not taken into account.

Running and results

When you press OK, the atom pairs that meet the conditions are added to the atomintr Renderer (named by Label set name) of the first molecule. If the Renderer does not exist, it is created, and the interactions are displayed as dotted lines with distance labels. The addition can be undone with a single Undo.

  • If no matching interaction is found, "No interaction was found" is shown and the dialog stays open.
  • Interactions beyond Max labels are not added. If that is not enough, Undo, increase Max labels, and run again.

The extracted interactions are the same as measurements made with the Distance tool in the tool palette. The display settings can be changed in the properties of atomintr.

Example: extracting interactions between two chains

To extract the interactions between chain A and chain B in PDB entry 1OX1 (trypsin and a substrate analog):

  1. Specify chain A as the first selection.
  2. Turn Second selection ON and specify chain B as the second selection.
  3. Leave the other items at their defaults and press OK.

Candidate interactions between chain A and chain B are added to measure.

Using it from the Console

In the native mode of the Console, analyze_interactions performs the same processing (see Console command list).

See also


Verified against: CueMol3 2.4.0.546